The required power of the MGT-40 gas turbine starter | ||
| Energy Equipment and Systems | ||
| مقاله 6، دوره 3، شماره 2، 2015، صفحه 137-142 اصل مقاله (1.08 M) | ||
| نوع مقاله: Research Paper | ||
| شناسه دیجیتال (DOI): 10.22059/ees.2015.56037 | ||
| نویسندگان | ||
| Saadat Zirak1؛ Hamid Ebrahimi2؛ Ahmad Reza Maissamy3 | ||
| 1Faculty of Mechanical Engineering Department Semnan University, Semnan, Iran | ||
| 2erospace Department Sharif University Of Technology Tehran, Iran | ||
| 3MapnaTurbine Company (TUGA), Karaj, Iran | ||
| چکیده | ||
| Determination of the starter torque-speed diagram is a major task in the design or selection of a proper gas turbine starter. In this paper, the maximum power of the MGT-40 gas turbine starter was calculated based on the dynamics of the rotor, start-up logic, and compressor map. In a recent research, the pressure ratio was assumed as a linear function of the rotor speed and the required starter power was calculated. In this study, the value is determined from the field data. To evaluate the proposed method, the results of obtained power were compared with that of the turbine performance reports. The comparison resulted in a reasonable engineering approximation. | ||
| کلیدواژهها | ||
| Compressor Map؛ Gas Turbine Starter؛ Start-up Logic؛ Start-up Power؛ Torque-Speed Diagram | ||
| مراجع | ||
|
| ||
|
آمار تعداد مشاهده مقاله: 1,525 تعداد دریافت فایل اصل مقاله: 859 |
||