| تعداد نشریات | 127 |
| تعداد شمارهها | 7,196 |
| تعداد مقالات | 77,227 |
| تعداد مشاهده مقاله | 157,219,166 |
| تعداد دریافت فایل اصل مقاله | 118,404,161 |
Rocking Concrete Shear Walls with Longitudinal-Perpendicular XADAS Dampers: Seismic Interaction with Moment Frames | ||
| Civil Engineering Infrastructures Journal | ||
| مقالات آماده انتشار، پذیرفته شده، انتشار آنلاین از تاریخ 22 مرداد 1404 اصل مقاله (2.45 M) | ||
| شناسه دیجیتال (DOI): 10.22059/ceij.2025.393248.2292 | ||
| نویسندگان | ||
| Farzin Vahid-Vahdattalab1؛ Elham Ghandi* 2؛ Erfan Shafei3 | ||
| 1Department of civil Engineering, Faculty of engineering, University of Mohaghegh Ardabili, Ardabil, Iran | ||
| 2Department of civil engineering, Faculty of engineering, University of Mohaghegh Ardabil, Ardabil, Iran | ||
| 3department of civil Engineering, Faculty of civil engineering, Urmia University of Technology, Urmia, Iran. | ||
| چکیده | ||
| This study explores the seismic interaction between a concrete moment-resisting frame and a rocking shear wall equipped with both longitudinal and perpendicular dampers. Unlike earlier works that placed dampers only along the wall’s length, this research introduces transverse dampers mounted perpendicularly using brackets. A parametric study examined how damper cross-sections affect displacement, drift, acceleration, and overturning safety. CFRP tendon post-tensioning forces were adjusted to ensure self-centering, with 160 KN per tendon found optimal. The structural response varied with damper cross-section. Unlike fixed-base systems where displacement consistently drops with larger dampers, rocking systems showed mixed trends. A 60×60 mm damper proved optimal for balancing displacement control and performance. Drift behavior followed conventional patterns, decreasing as damper size increased. A 246.7% drift reduction was observed with a 60×40 mm damper during the Kocaeli earthquake, but the 60×60 mm configuration with an MR/MO ratio of 0.93 was overall the most effective, combining stability and energy dissipation. Drift improvements became notable only after a specific damper size threshold, supported by time-history analysis from seven earthquakes. The study also found that the damper arrangement along the wall’s edges significantly affects the overturning safety factor, particularly in rocking systems. | ||
| کلیدواژهها | ||
| Rocking Shear Wall؛ CFRP Tendons؛ Combined Damper Installation؛ XADAS Dampers؛ Time- History Analysis | ||
|
آمار تعداد مشاهده مقاله: 433 تعداد دریافت فایل اصل مقاله: 237 |
||