On Compressive Stress-Strain Behavior of Standard Half-Scale Concrete Masonry Prisms | ||
Civil Engineering Infrastructures Journal | ||
دوره 55، شماره 2، اسفند 2022، صفحه 293-307 اصل مقاله (634.11 K) | ||
نوع مقاله: Research Papers | ||
شناسه دیجیتال (DOI): 10.22059/ceij.2022.324782.1758 | ||
نویسندگان | ||
Ehsan Kahrizi1؛ Reza Aghayari* 2؛ Masumeh Bahrami3؛ Hamid Toopchinezhad2 | ||
1M.Sc., Department of Civil Engineering, Razi University, Kermanshah, Iran. | ||
2Associate Professor, Department of Civil Engineering, Razi University, Kermanshah, Iran. | ||
3Ph.D. Candidate, Department of Civil Engineering, Razi University, Kermanshah, Iran. | ||
چکیده | ||
Masonry buildings are the most utilized structural system worldwide due to the ease of construction and cost-effectiveness. The effective design of masonry structures has been always an important research subject. Experimental studies are the main component of such research studies. The budget and equipment limitations may challenge the laboratory testing of full-scale masonry specimens and test structures. As such, the use of model-scale specimens may be found as a promising alternative to study the response behavior of this type of structure. In this paper, the stress-strain behavior of half-scale concrete masonry units and prisms (hollow and fully grouted) under compressive loads is evaluated and compared with their full-scale counterparts. The half-scale specimens are standard in that the principles of similitude law have been followed precisely in their aggregate grading, mix-design, physical dimensions, and loading. The stress-strain diagram and failure modes of the half-scale are similar to those of the full-scale. The ratio of half-scale to the full-scale compressive strength of the hollow and grouted masonry prisms on average was found to be 1.07, and 1.08, respectively. The experimentally-evaluated response of the standard half-scale specimens that fully satisfy the requirements of similitude law may be extended with good accuracy to the full-scale masonry. | ||
کلیدواژهها | ||
Compression Test؛ Concrete Masonry؛ Prism Testing؛ Small-Scale Modeling | ||
مراجع | ||
AbdelRahman, B. and Galal, K. (2020). "Influence of pre-wetting, non-shrink grout, and scaling on the compressive strength of grouted concrete masonry prisms", Construction and Building Materials, 241, 117985.
ACI 530. (2013). Building code requirements and specification for masonry structures and companion commentaries, American Concrete Institute.
Alvarenga, R.C.S.S., Nalon, G.H., Fioresi, L.A.F., Pinto, M.C., Pedroti, L.G. and Ribeiro, J.C.L. (2017) "Experimental evaluation of the influence of mortar’s mechanical properties on the behavior of clay masonry", In Characterization of Minerals, Metals, and Materials, 2017, 671-679, Springer, Cham.
Andria, I., Samira, R., Mark, H., Pedram, K. and Nigel, SH. (2017). "Testing and finite element modeling of concrete block masonry in compression", 13th Canadian Masonry Symposium, Halifax, Canada.
ASTM C90-16a. (2016). Standard specification for loadbearing concrete masonry units, American Society for Testing and Materials, West Conshohocken, Pa.ASTM C136/C136M-19. (2019). Standard test method for sieve analysis of fine and coarse aggregate, American Society for Testing and Materials, West Conshohocken, Pa.
ASTM C140-13a. (2013a). Standard test methods for sampling and testing concrete masonry units and related units, American Society for Testing and Materials, West Conshohocken, Pa.
ASTM C144-04. (2018). Standard specification for aggregate for masonry mortar, American Society for Testing and Materials, West Conshohocken, Pa.
ASTM C270-19. (2019). Standard specification for mortar for unit masonry, American Society for Testing and Materials, West Conshohocken, Pa.
ASTM C426-16. (2016). Standard test method for linear drying shrinkage of concrete masonry units, American Society for Testing and Materials, West Conshohocken.
ASTM C404-18. (2018). Standard specification for aggregates for masonry grout, American Society for Testing and Materials, West Conshohocken, Pa.
ASTM C476-19. (2019). Standard specification for grout for masonry, American Society for Testing and Materials, West Conshohocken, Pa.
ASTM C1314-12. (2012). Standard test method for compressive strength of masonry prisms, American Society for Testing and Materials, West Conshohocken, Pa.
Camacho, J.S., Logullo, B.G., Parsekian, G. and Soudias, P.R. (2015). "The Influence of grouting and reinforcement ratio in the concrete block masonry compressive behavior", Revista IBRACON de Estruturas e Materiais, 8, 341-364.Camacho, J.S. and Andolfato, R.P. (2000). "Development of the production techniques of the small scale concrete block", 12th International Brick/Block Masonry Conference, Madrid-Spain.CSA Standard A165. (2002). Concrete materials and methods of concrete construction, methods of test for concrete, Canadian Standards Association, Toronto.
Drysdale, R.G., Hamid, A.A. and Baker, L.R. (1994). Masonry structures: Behavior and design, Prentice-Hall, Englewood Cliffs, N.J.
Eshghi, S. and Pourazin, Kh. (2009). "In-plane behavior of confined masonry walls, with and without opening", International Journal of Civil Engineering, 7(1), 49-60.
Eurocode 6-1996-1-1, 1996-3. (2006). Design of masonry structures, Part 1-1: Rules for reinforced and unreinforced masonry, Part 3: Simplified calculation methods for unreinforced masonry structures, European Committee for Standardization, Brussels.
Gustavo, H., Carol. F. and Leonardo, G. (2019). "Strength and failure mechanisms of masonry prisms under compression, flexure and shear: Components’ mechanical properties as design constraints", Journal of Building Engineering, 28, 101038.
Hamid, A.A., Abboud, B.E. and Harris, H.G. (1985). "Direct modeling of concrete block masonry under axial compression", In Masonry: Research, Application, and Problems, ASTM International.
Harris H.G. and Sabnis, G. (1999). Structural modeling and experimental techniques, CRC press.
Hassanli, R., ElGawady, M.A. and Mills, J.E. (2015). "Effect of dimensions on the compressive strength of concrete masonry prisms", Advances in Civil Engineering Materials, 4(1), 175-201.
Hosseinijou, S.A. and Mansour, S. (2021). "Dynamic material flow analysis of cement in Iran: New insights for sustainability of civil infrastructures", Civil Engineering Infrastructures Journal, 54(2), 381-403.
Huang, L., Long, L. and Yan, L. (2014). "Compressive strength of double H concrete block masonry prisms", Journal of Materials in Civil Engineering, 26(8), 06014019.
Jablonsky, N. (1996). Mix design for concrete block, proportioning using the fineness modulus method, The Aberdeen Group, 1-4.
Long, L., Hamid, A. and Drysdale, R.G. (2005). "Small-scale modeling of concrete masonry using half-scale units: A preliminary study", 10th Canadian Masonry Symposium, Banff Alberta, June 8-12.
Mohammad, G., Eduardo, R., Almir, B. and Roman, H. (2010). "Influence of vertical joint on the mechanical behavior of concrete block masonry", Engenharia Estudo, 10(1), 75-80.
Oliveira, R., Martin, G. and Nalon, G.H. (2018). "Influence of blocks and grout on compressive strength and stiffness of concrete masonry prisims", Construction and Building Materials, 182, 233-241.
Rai, D.C. (2002). Review of design codes for masonry buildings, Indian Institute of Technology, Kanpur, India.
Sathiparan, N., Anjalee, W.A.V. and Kandage, K.K.S. (2016). "The scale effect on small-scale modelling of cement block masonry", Materials and Structures, 49(7), 2935-2946.
Standard No. 2800. (2013). Iranian code of practice for seismic resistant design of building, 4th Edition, Ministry of Urban and Road Construction, Tehran.
Zahra, T., Thamboo, J. and Asad, M. (2021). "Compressive strength and deformation characteristics of concrete block masonry made with different mortars, blocks and mortar beddings types", Journal of Building Engineering, 38, 102213. | ||
آمار تعداد مشاهده مقاله: 313 تعداد دریافت فایل اصل مقاله: 701 |