Effects of Fluid Environment Properties on the Nonlinear Vibrations of AFM Piezoelectric Microcantilevers | ||
Journal of Ultrafine Grained and Nanostructured Materials | ||
مقاله 6، دوره 50، شماره 2، اسفند 2017، صفحه 117-123 اصل مقاله (1.06 M) | ||
نوع مقاله: Research Paper | ||
شناسه دیجیتال (DOI): 10.22059/jufgnsm.2017.02.06 | ||
نویسندگان | ||
Masoud Ahmadi1؛ Reza Ansari* 1؛ Mansour Darvizeh1؛ Hessam Rouhi2 | ||
1Department of Mechanical Engineering, University of Guilan, Rasht, Iran. | ||
2Department of Engineering Science, Faculty of Technology and Engineering, East of Guilan, University of Guilan, Rudsar-Vajargah, Iran. | ||
چکیده | ||
Nowadays, atomic-force microscopy plays a significant role in nanoscience and nanotechnology, and is widely used for direct measurement at atomic scale and scanning the sample surfaces. In tapping mode, the microcantilever of atomic-force microscope is excited at resonance frequency. Therefore, it is important to study its resonance. Moreover, atomic-force microscopes can be operated in fluid environments such as their applications in chemical and biological sensors. Additionally, piezoelectric microcantilevers are used to enhance atomic-force microscope scanning. Motivated by these considerations, presented herein is a finite element investigation into the nonlinear vibration behavior of piezoelectric microcantilever of atomic-force microscopes in fluid environment. For this purpose, a 3D finite element model coupled with a computational fluid dynamics model is introduced based upon a fluid-solid interaction analysis. First, the reliability of present fluid-solid interaction analysis is revealed by comparison with experimental data available in the literature. Then, numerical results are presented to study the influences of fluid dynamic viscosity and density on the resonance frequency, resonance amplitude and time response of piezoelectric microcantilever. It was shown that increasing the fluid density and dynamic viscosity results in the decrease of resonance frequency. For example, for density equal to 1000 kg/m3 , increasing the viscosity of fluid environment from 0.1 to 1, 10 and 20 mPa.s leads to decrease of resonance frequency about 3%, 29% and 42%, respectively. Also, the resonance amplitude of microcantilever increases as the density increases, while increasing dynamic viscosity has a decreasing effect on the resonance amplitude. | ||
کلیدواژهها | ||
Piezoelectric microcantilever؛ Atomic-force microscopy؛ Nonlinear vibration؛ Fluid-solid interaction analysis | ||
مراجع | ||
1. Binnig G, Quate CF, Gerber C. Atomic Force Microscope. Physical Review Letters. 1986;56(9):930-3.
14. Salehi, Mi., Marashi, P., Salehi, Ma., and Ghannad, R., 2014, “Optimization of the FeCo nanowire fabrication embedded in anodic aluminum oxide template by response surface methodology,” J. Ultrafine Grained Nanostruct. Mater., 47, pp. 27-35.
23. García R. Dynamic atomic force microscopy methods. Surface Science Reports. 2002;47(6-8):197-301.
| ||
آمار تعداد مشاهده مقاله: 1,136 تعداد دریافت فایل اصل مقاله: 795 |